Situation B: MY THERMOSTAT LINKS TO TH/TR/TH-TR. IF AN EXTRA is had by you CABLE

Situation B: MY THERMOSTAT LINKS TO TH/TR/TH-TR. IF AN EXTRA is had by you CABLE

In case your thermostat cables hook up to terminals marked Th, Tr, and Th-Tr, they truly are most most likely connecting to a gasoline valve.

But, it is important to locate the wires linking towards the gasoline valve and follow them into the transformer that is 24VAC the heating gear to spot where your “C” connection should be. In the event that you need assistance with this, be sure to contact ecobee help.

Merely link the free cable towards the typical connection point.

IF YOU’VE GOT NO ADDITIONAL WIRES

Should you not have any extra cables, you’ve got two choices:

    • Run a extra cable at your thermoregulator down to your gear
  • Buy and put in a Fast-Stat Common Maker

ALTERNATE SOLUTION: 24VAC TRANSFORMER that is PLUG-IN

A different would be to power the ecobee by having an outside plug-in transformer that is 24VAC.

This transformer could be attached to a wall surface, and could be wired the following:

  • The 24VAC transformer cables would connect with RC and C from the ecobee
  • The two cables in your old thermostat would connect with RH and W1 in the ecobee

NOTE: make sure the transformer can perform 24V AC output ( maybe perhaps not DC production)

Situation C:MY THERMOSTAT CONNECTS TO T/T TERMINALS

When your thermostat cables connect with T/T terminals, observe that you will need a different 24VAC transformer to power the ecobee. It’s also possible to need extra elements.

T/T connections usually suggest a link to a tool referred to as an Aquastat.

IF YOU HAVE GOT AN ADDITIONAL CABLE

When you yourself have an additional cable, you will need an isolation relay and an independent 24VAC transformer.

ecobee calls for an isolation relay by having a 24vac coil and Normally Open (N/O) connections.

IF NO EXTRA is had by you WIRES

When you yourself have no additional cables, you will need both a Fast-Stat popular Maker and a split 24VAC transformer

ALTERNATE SOLUTION: 24VAC PLUG-IN TRANSFORMER

Another solution would be to power the ecobee having an outside plug-in transformer that is 24VAC.

This transformer are connected to a wall, and will be wired the following:

  • The 24VAC transformer cables would hook up to RC and C in the ecobee
  • The 2 cables on your own old thermostat would connect with RH and W1 from the ecobee

NOTE: make sure the transformer is with the capacity of 24V AC production ( maybe not DC production)

NOTE (2): Some T/T connections may well not work reliably whenever linked straight to the Rh and W1 terminals associated with ecobee. If that’s the case, a 24 VAC transformer and isolation relay regarding the gear part will be necessary (see details under “FOR THOSE WHO HAVE AN ADDITIONAL WIRE” above).

When you yourself have a couple of thermostats managing your home heating:

Should your home heating is managed by significantly more than one thermoregulator, the body most most likely has area valves or even an area control relay.

Please touch base to ecobee help aided by the information that is following purchase to find out compatibility and appropriate installation guidelines:

  • Exactly exactly just How numerous thermostats you have actually as a whole for the home heating
  • Photos regarding the wiring at each thermostat
  • Photos for the wiring at any area valves or area panels
  • The make and model of every area valve and/or area panels
  • The https://brightbrides.net/ sheer number of extra cables which are behind the wall surface at each thermostat

If you should be having trouble determining your zone valves or zone panels, some widely used brand names for area valves/zone control gear consist of:

  • Taco
  • Honeywell
  • Erie
  • Energy Kinetics