Cool water supply – Kenmore Coldspot 106 consumer handbook

Cool water supply – Kenmore Coldspot 106 consumer handbook

Web Page 8

Read all instructions very carefully before beginning. SIGNIFICANT;

If running the ice box before setting up the water connection, turn ice manufacturer into the OFF position to avoid procedure without water.

All installments must certanly be prior to regional plumbing system

Utilize copper tubing and always check for leaks.

Install copper tubing only in places where temperatures will stay above freezing.

If might take as much as twenty four hours for the ice maker to begin with ice that is producing.

Tools needed;

in. open-end wrenches or two adjustable

Hand drill or electric drill (correctly grounded)

Your fridge dealer features a kit available by having a

in. (6.35 mm) saddle-type shut-off valve, a union, and copper

tubing. Before buying, make certain a saddle-type valve

complies along with your regional plumbing work codes. Don’t use a piercingВ­

in. (4.76 mm) seat valve which decreases water movement

and clogs more easily.

Cool water supply

The ice manufacturer water valve contains a movement washer that is utilized

being a water force regulator. The ice manufacturer should be attached to a cool water line with water force between 30 and 120 psi. If your problem happens, phone your energy business.

Linking to water line:

1. Unplug disconnect or refrigerator energy.

Turn OFF main water supply. Switch on faucet that is nearest very very long

sufficient to line that is clear of.

water pipe close to the ice box.

Horizontal pipeline will continue to work, however the following procedure

must certanly be followed: Drill regarding the top region of the pipeline, perhaps not the underside. This may help in keeping water from the drill. And also this keeps normal sediment from gathering within the valve.

To look for the duration of copper tubing you shall need,

measure from connection on lower rear that is left of to

water pipeline. Add 7 ft. (2.1 m) to accommodate going fridge for cleansing. utilize 14 in. (6.35 mm) O.D. (outside diameter)

copper tubing. Make sure both ends of copper tubing are cut square.

Employing a grounded drill, drill a 14 in. gap into the water pipe that is cold

you’ve got chosen.

1. Cool Water Pipe

2. Pipe Clamp

3. Copper Tubing

4. Compression Nut

5. Compression Sleeve

6. Shut-Off Valve

7. Packing Nut

Fasten shut-off valve to water that is cold with pipeline clamp. Be

certain socket end is sturdily into the 14 in. drilled opening into the water

pipe and that washer is beneath the pipeline clamp. Tighten packing nut. Tighten the pipeline clamp screws very very very carefully and

evenly so washer makes a watertight seal. Usually do not overtighten or you might crush the copper tubing, particularly if soft (coiled) copper tubing is employed. So Now you will be ready to connect the copper tubing.

Slide compression nut on copper tubing https://besthookupwebsites.net/fastflirting-review/ as shown. Insert end of tubing into outlet end squarely in terms of it shall get. Screw compression nut onto socket end with adjustable wrench. Usually do not overtighten.

Place the free end of this tubing in to a container or sink, and

switch on water that is main and flush out tubing until water is clear. Turn fully off shut-off valve in the water pipeline. Coil copper tubing.

Linking to fridge:

1. Connect the copper pipe towards the valve inlet utilizing a compression

nut and sleeve as shown. Fasten the compression nut. Usually do not overtighten. Make use of the pipe clamp regarding the relative back for the

fridge to secure the tubing into the refrigerator as shown. This may help alleviate problems with harm to the tubing as soon as the ice box is forced straight back up against the wall surface. Go on to step two.

2. Turn shut-off valve ON. Search for leakages.

connections (including connections during the valve) or nuts that

Copper Tubing

3. Compression Nut

4. Valve Inlet

The ice manufacturer comes with a integrated water strainer. If

neighborhood water conditions need regular cleansing or a well is

your way to obtain water supply, a second water strainer should

be set up within the

in. (6.35 mm) water line. Obtain a water

strainer from your appiiance dealer that is nearest. Install at either tube connection.